接地装置在配电中的安装技巧

文章(zhang)出处:人气:91发表时间(jian):2021-01-02 10:16:24

接(jie)地(di)在(zai)配电(dian)(dian)柜(ju)中(zhong)(zhong)(zhong)和(he)建(jian)筑(zhu)中(zhong)(zhong)(zhong)应用(yong)极广,又叫接(jie)地(di)线(xian)在(zai)配电(dian)(dian)中(zhong)(zhong)(zhong)一般用(yong)黄绿双色线(xian)表示。是利用(yong)大地(di)为电(dian)(dian)力系统正常运行(xing)、漏(lou)电(dian)(dian)发生故障和(he)遭(zao)受雷(lei)击(ji)等情况(kuang)下(xia)提供对地(di)电(dian)(dian)流(liu)的(de)回(hui)路,家(jia)电(dian)(dian)设(she)备一旦漏(lou)电(dian)(dian),由(you)于大地(di)电(dian)(dian)阻比人体(ti)电(dian)(dian)阻小。漏(lou)电(dian)(dian)电(dian)(dian)流(liu)会导(dao)入(ru)地(di)下(xia),从而保证了(le)人员安(an)全(quan)和(he)整个电(dian)(dian)力系统中(zhong)(zhong)(zhong)包括(kuo)发电(dian)(dian)、变电(dian)(dian)、输电(dian)(dian)、配电(dian)(dian)和(he)用(yong)电(dian)(dian)各(ge)个环节的(de)电(dian)(dian)气(qi)(qi)设(she)备的(de)安(an)全(quan)。因此,所有电(dian)(dian)气(qi)(qi)设(she)备或高层(ceng)建(jian)筑(zhu)都(dou)要(yao)可靠(kao)接(jie)地(di)。

接(jie)(jie)(jie)(jie)地就是或装置的(de)(de)(de)(de)某一点(dian)(接(jie)(jie)(jie)(jie)地点(dian))与大地之间有(you)着可靠的(de)(de)(de)(de)又符合技(ji)术要(yao)(yao)求(qiu)的(de)(de)(de)(de)电(dian)(dian)连接(jie)(jie)(jie)(jie)。该接(jie)(jie)(jie)(jie)点(dian)对电(dian)(dian)阻有(you)着极高(gao)(gao)的(de)(de)(de)(de)要(yao)(yao)求(qiu),阻值太高(gao)(gao)起不(bu)了保(bao)(bao)护(hu)(hu)作用(yong)。接(jie)(jie)(jie)(jie)地可分为工作接(jie)(jie)(jie)(jie)地(如配电(dian)(dian)变(bian)压器(qi)(qi)低压侧中性点(dian)接(jie)(jie)(jie)(jie)地和避雷器(qi)(qi)、避雷线的(de)(de)(de)(de)接(jie)(jie)(jie)(jie)地)和保(bao)(bao)护(hu)(hu)接(jie)(jie)(jie)(jie)地(如各种电(dian)(dian)气(qi)设备(bei)、装置和用(yong)电(dian)(dian)器(qi)(qi)具(ju)的(de)(de)(de)(de)金属(shu)外壳接(jie)(jie)(jie)(jie)地)等。

一(yi)、接(jie)地(di)装置的分类和技(ji)术要求

1.接(jie)地装置(zhi)(zhi)如图6-1所示,是由接(jie)地体(ti)和接(jie)地线两(liang)部分(fen)组成。接(jie)地装置(zhi)(zhi)以接(jie)地体(ti)的多少,分(fen)为三种组成形式。

(1)单极接(jie)(jie)(jie)地(di)(di)由一支接(jie)(jie)(jie)地(di)(di)体(ti)构(gou)成,接(jie)(jie)(jie)地(di)(di)线一端与接(jie)(jie)(jie)地(di)(di)体(ti)连接(jie)(jie)(jie),另一端与设备的接(jie)(jie)(jie)地(di)(di)点(dian)直接(jie)(jie)(jie)连接(jie)(jie)(jie)(图(tu)6-2)。它适用于接(jie)(jie)(jie)地(di)(di)要求不太高(gao)和设备接(jie)(jie)(jie)地(di)(di)点(dian)较少的场所。

接地装置安装方式.jpg

(2)多极接(jie)地装置

由两(liang)支以(yi)上接(jie)(jie)地体(ti)构成(cheng),各接(jie)(jie)地体(ti)之间用接(jie)(jie)地干(gan)线(xian)(xian)连成(cheng)一体(ti),形成(cheng)并(bing)联,从面减(jian)小了(le)接(jie)(jie)地装置(zhi)的接(jie)(jie)地电阻。接(jie)(jie)地支线(xian)(xian)一端(duan)与(yu)接(jie)(jie)地干(gan)线(xian)(xian)连接(jie)(jie),另一端(duan)与(yu)设备的接(jie)(jie)地点直接(jie)连(lian)接(jie)(图6-3)。多极接(jie)地(di)装置可靠性(xing)强,适用于接(jie)地(di)要求较(jiao)高,而(er)设备接(jie)地(di)点较(jiao)多的场所

(3)接地网络(luo)

由多(duo)支接(jie)地(di)(di)(di)体(ti)用接(jie)地(di)(di)(di)干线将其(qi)互(hu)相连(lian)接(jie)所形成(cheng)的(de)(de)(de)网络(luo)。图6一4所示是(shi)接(jie)地(di)(di)(di)网络(luo)常见的(de)(de)(de)形状,接(jie)地(di)(di)(di)网络(luo)既方便机群设备的(de)(de)(de)接(jie)地(di)(di)(di)需要(yao),又加(jia)强了(le)(le)接(jie)地(di)(di)(di)装(zhuang)置(zhi)的(de)(de)(de)可靠(kao)性,也减小了(le)(le)接(jie)地(di)(di)(di)电阻。适(shi)用于配(pei)电所以及接(jie)地(di)(di)(di)点多(duo)的(de)(de)(de)车间(jian)、工场或露天作业等场所地(di)(di)(di)体(ti)楼地(di)(di)(di)线地(di)(di)(di)平程触体(ti)图6-4接(jie)地(di)(di)(di)同络(luo)图6-3多(duo)极接(jie)地(di)(di)(di)装(zhuang)置(zhi)(a)方孔接(jie)地(di)(di)(di)同(b)长孔接(jie)网

2.接地(di)装(zhuang)置(zhi)的(de)技术(shu)要求

接(jie)(jie)(jie)(jie)地(di)(di)装(zhuang)置的技(ji)术要求主要是接(jie)(jie)(jie)(jie)地(di)(di)电(dian)阻(zu)(zu),原则上(shang)接(jie)(jie)(jie)(jie)地(di)(di)电(dian)阻(zu)(zu)越(yue)小(xiao)越(yue)好(hao),考虑到经济合理,接(jie)(jie)(jie)(jie)地(di)(di)电(dian)阻(zu)(zu)以(yi)不(bu)(bu)超过规定的数值为(wei)准对接(jie)(jie)(jie)(jie)地(di)(di)电(dian)阻(zu)(zu)的要求:避(bi)雷(lei)针和避(bi)雷(lei)线单独使(shi)用(yong)时的接(jie)(jie)(jie)(jie)地(di)(di)电(dian)阻(zu)(zu)小(xiao)于10欧,而配电(dian)变压(ya)器低压(ya)侧中性点(dian)接(jie)(jie)(jie)(jie)地(di)(di)电(dian)阻(zu)(zu)应(ying)在(zai)0.5~10欧之间,保护接(jie)(jie)(jie)(jie)地(di)(di)的接(jie)(jie)(jie)(jie)地(di)(di)电(dian)阻(zu)(zu)应(ying)不(bu)(bu)小(xiao)于4欧。几个设备共用(yong)一副接(jie)(jie)(jie)(jie)地(di)(di)装(zhuang)置,接(jie)(jie)(jie)(jie)地(di)(di)电(dian)阻(zu)(zu)应(ying)按要求量高的为(wei)准。

接地装置多极接地.jpg

二(er)、接(jie)地体的安装方(fang)式

1.人(ren)工接地体一般都是用(yong)结构钢(gang)制成,其规(gui)格如(ru)下;角(jiao)钢(gang)的厚(hou)度应不小(xiao)(xiao)于(yu)4毫(hao)(hao)米(mi),钢(gang)管管壁厚(hou)度不小(xiao)(xiao)手3.5毫(hao)(hao)米(mi),圆钢(gang)直(zhi)径不小(xiao)(xiao)于(yu)8毫(hao)(hao)米(mi),扇钢(gang)厚(hou)度不小(xiao)(xiao)于(yu)4毫(hao)(hao)米(mi)、截面积不小(xiao)(xiao)于(yu)48平(ping)方毫(hao)(hao)米(mi)。材(cai)料不应有(you)严重锈烛,弯(wan)曲的材(cai)料必须校正后方可使用(yong)。

2.人(ren)工接(jie)地体的安装方法

(1)垂直(zhi)安装方法

1)垂直(zhi)安装(zhuang)接地体(ti)的制作方法(fa)

垂直(zhi)安(an)装接(jie)地体通常(chang)用角(jiao)钢(gang)或钢(gang)管(guan)制成,长度一般(ban)在(zai)23米之(zhi)间(jian),但不(bu)能小于(yu)2米。下端要(yao)(yao)加工成尖形。用角(jiao)钢(gang)制作的(de),其(qi)尖点(dian)应在(zai)角(jiao)钢(gang)的(de)钢(gang)脊(ji)上,且(qie)两个斜边(bian)要(yao)(yao)对(dui)称。用钢(gang)管(guan)制作的(de),要(yao)(yao)单边(bian)斜削保持一个尖点(dian)。凡用螺钉连(lian)接(jie)的(de),应先钻(zuan)好螺钉孔(kong)。为便(bian)于(yu)连(lian)接(jie),要(yao)(yao)在(zai)接(jie)地体的(de)上做图所示的(de)安(an)排

2)安装方法(fa):采用打桩法(fa)将接(jie)(jie)地(di)(di)体打入地(di)(di)下(xia),接(jie)(jie)地(di)(di)体应与地(di)(di)面(mian)(mian)垂直,不可正斜(xie),打下(xia)地(di)(di)面(mian)(mian)的(de)有(you)效深度不少于2米。多极接(jie)(jie)地(di)(di)或接(jie)(jie)地(di)(di)网的(de)接(jie)(jie)地(di)(di)体与接(jie)(jie)地(di)(di)体之间在地(di)(di)面(mian)(mian)下(xia)应保持2.5米以上的(de)直线(xian)距离

用锤子旋打(da)角(jiao)(jiao)钢(gang)时,应(ying)蔽打(da)在(zai)角(jiao)(jiao)钢(gang)的(de)(de)角(jiao)(jiao)脊(ji)处。若是钢(gang)管,则(ze)(ze)锤击力应(ying)集中(zhong)在(zai)尖端的(de)(de)切点位(wei)置,否则(ze)(ze)不但打(da)入图难,且不易打(da)直,遭成(cheng)接(jie)地(di)体(ti)(ti)与(yu)土(tu)壤产生缝隙,增加接(jie)触电(dian)阻接(jie)地(di)体(ti)(ti)打(da)入地(di)面后,应(ying)在(zai)其(qi)(qi)四周填(tian)土(tu)旁实,以减小接(jie)触电(dian)阻。若接(jie)地(di)体(ti)(ti)与(yu)接(jie)地(di)体(ti)(ti)连接(jie)干线(xian)在(zai)地(di)面下(xia)连接(jie),应(ying)先(xian)将其(qi)(qi)电(dian)焊(han)焊(han)接(jie)后,再填(tian)土(tu)夯实。

接地装置不同安装方式.jpg

(2)水平(ping)安装方法。

水平安装(zhuang)接(jie)(jie)地体,一般只(zhi)适用于(yu)土层浅(qian)薄的(de)(de)地方,接(jie)(jie)地体通常用扇钢或元(yuan)钢制成。一端(duan)弯成直(zhi)角向上,便于(yu)连接(jie)(jie):如果与接(jie)(jie)地线采(cai)用螺(luo)(luo)钉压接(jie)(jie),应(ying)先(xian)钻好螺(luo)(luo)钉孔。接(jie)(jie)地体的(de)(de)长度随安装(zhuang)条件和接(jie)(jie)地装(zhuang)置的(de)(de)结(jie)构形式面定。

安装(zhuang)采用挖沟(gou)填埋(mai)法,接(jie)地(di)体(ti)(ti)应埋(mai)入地(di)面0.6米以下的土壤中,如果是多(duo)地(di)或(huo)接(jie)地(di)网,接(jie)地(di)体(ti)(ti)之间应相隔2.5米以上的直线距离。

(3)在土壤电(dian)阻率较高的地(di)(di)层,安装接接地(di)(di)支线地(di)(di)体,必须(xu)采取(qu)以下三个措(cuo)施:

1)在土壤电阻率不太高的地层,要增至少至少0,6米接地干线加接地体的支(zhi)数。

2)在(zai)(zai)土壤电阻率较高的(de)地(di)层,可在(zai)(zai)每(mei)接(jie)(jie)地(di)体图(tu)6-7水平(ping)安装接(jie)(jie)地(di)体支(zhi)接(jie)(jie)地(di)体周围0.5米以下,1.2米以上的(de)地(di)层中填放化学填料(liao)。每(mei)份(fen)化学填料(liao)的(de)配制方法:先将(jiang)8千(qian)克(ke)食(shi)盐溶(rong)解在(zai)(zai)适量的(de)水中,然(ran)后将(jiang)其逐(zhu)渐(jian)浇入(ru)30克(ke)木炭(tan)粉中,并不(bu)断搅拌,均匀后填入(ru)接(jie)(jie)地(di)体四周。

3)在(zai)土(tu)壤电(dian)阻率很高的地层,应采用挖坑(keng)换土(tu)的方法 

以(yi)上(shang)对接地装置安装做(zuo)了(le)较详(xiang)细的介(jie)绍,在配(pei)电(dian)设(she)备(bei)和高层建筑中(zhong)一定要做(zuo)好保(bao)(bao)护接地装置。这样(yang)可以(yi)有效地避免用(yong)电(dian)设(she)备(bei)漏电(dian)和遭受雷击。极大地保(bao)(bao)护了(le)人员(yuan)和用(yong)电(dian)设(she)备(bei)的安全。


热销产(chan)品 了解更多+

配电柜生产厂家为您提供最新,最全,最权威的低压配电柜成套、配电箱、plc控制柜行业信息和恒温恒湿控制柜价格咨询服务,最专业的技术指导,做中国最有影响力的配电设备生产供应商

地址:广东(dong)省广州市番禺区石基镇金(jin)龙路44号中润工(gong)业园(yuan)

24小时服务热线(xian):13697432957 电子(zi)邮箱:253106211@qq.com

全国销售区域:广东深(shen)圳、东莞(guan)、佛(fo)山(shan)(shan)(shan)、惠州、中山(shan)(shan)(shan)、珠海,广西(xi)(xi)(xi),安徽,福建,江西(xi)(xi)(xi),河南(nan),河北,湖北,湖南(nan),海南(nan),四川,贵州,云(yun)南(nan),陕西(xi)(xi)(xi),甘肃,山(shan)(shan)(shan)西(xi)(xi)(xi),内蒙古,宁夏

Copyright 2001 - 2015    广州(zhou)J9九游会AG电(dian)控设备有限公(gong)司(si)

广(guang)州J9九游会AG自动(dong)化控制设备(bei)有(you)限公司

友链: 


扫(sao)一(yi)扫(sao),免费体验电控解决方(fang)案(an)

二维码1 二维码1

在线客服

二维码1
咨询热线 13697432957